INDRAWATI, TITIK (2015) PENURUNAN KADAR Cr(VI) PADA LIMBAH CAIR LABORATORIUM MENGGUNAKAN SERBUK BESI LIMBAH INDUSTRI ELEKTROPLATING. Bachelor thesis, UNIVERSITAS MUHAMMADIYAH PURWOKERTO.
TITIK INDRAWATI COVER.pdf
Download (1MB)
TITIK INDRAWATI BAB I.pdf
Download (624kB)
TITIK INDRAWATI BAB II.pdf
Download (1MB)
TITIK INDRAWATI BAB III.pdf
Restricted to Registered users only
Download (638kB)
TITIK INDRAWATI BAB IV.pdf
Restricted to Registered users only
Download (876kB)
TITIK INDRAWATI BAB V.pdf
Restricted to Registered users only
Download (628kB)
TITIK INDRAWATI DAFTAR PUSTAKA.pdf
Download (824kB)
TITIK INDRAWATI LAMPIRAN.pdf
Restricted to Registered users only
Download (2MB)
Abstract
Liquid waste generated from the testing activities COD(Chemical Oxygen Demand) in the laboratory containing Cr(VI) which is highly toxic and potentially pollute the environment . It required a processing method according to the characteristics of the waste. In this study examined removal of Cr ( VI ) using iron waste of electroplating industry. The goal is to get the best iron mass and temperature as well as determine the equilibrium constant according to Freundlich and Langmuir adsorption . The independent variables used are iron mass and temperature . Mass variation iron used is 0.5 g , 1 g , 1.5 g , 2 g , 2.5 g , while the temperature variation of 30 , 40 ° C , 50oC and 56oC . Fixed variable used is pH 2 , the contact time of 20 minutes and stirring speed of 120 rpm . Test levels of Cr ( VI ) was conducted using SNI 06-6989.53-2005 . The results revealed that the iron powder electroplating waste could reduce levels of Cr ( VI ) optimally on the addition of iron masses as much as 2.0 which is an average of 89.00 % at various temperatures . Optimal temperature that can reduce levels of Cr ( VI ) is the temperature 56oC with the percentage of 85.55 % . In this research, the equilibrium constant of Freundlich , KF is 4.1570 and n is 0.5685 with an error of 7.68 % , while the Langmuir equilibrium constant , qmax is -0.0434 and -6.4994 with bl is an error of 3.81 %
| Dosen Pembimbing: | unspecified | unspecified |
|---|---|
| Item Type: | Thesis (Bachelor) |
| Additional Information: | Pembimbing: Anwar Ma’ruf., ST.,MT. dan Endar Puspawiningtiyas.,ST,.MT. |
| Uncontrolled Keywords: | levels of Cr ( VI ) , laboratory liquid waste , iron powder , Freundlich and Langmuir equilibrium constant |
| Subjects: | T Technology > TP Chemical technology |
| Divisions: | Fakultas Tekniik Dan Sains > Teknik Kimia S1 |
| Depositing User: | Dan Kh |
| Date Deposited: | 09 Jan 2018 04:16 |
| Last Modified: | 05 Sep 2024 00:51 |
| URI: | http://repository.ump.ac.id/id/eprint/6881 |