ESTIKA, DENILLA (2017) VALIDASI METODE ANALISIS METOPROLOL DALAM URIN MANUSIA SECARA KROMATOGRAFI LAPIS TIPIS DENSITOMETRI. Bachelor thesis, UNIVERSITAS MUHAMMADIYAH PURWOKERTO.

[thumbnail of DENILLA ESTIKA COVER.pdf]
Preview
Text
DENILLA ESTIKA COVER.pdf

Download (869kB) | Preview
[thumbnail of DENILLA ESTIKA BAB I.pdf]
Preview
Text
DENILLA ESTIKA BAB I.pdf

Download (645kB) | Preview
[thumbnail of DENILLA ESTIKA BAB II.pdf]
Preview
Text
DENILLA ESTIKA BAB II.pdf

Download (612kB) | Preview
[thumbnail of DENILLA ESTIKA BAB III.pdf] Text
DENILLA ESTIKA BAB III.pdf
Restricted to Registered users only

Download (585kB)
[thumbnail of DENILLA ESTIKA BAB IV.pdf] Text
DENILLA ESTIKA BAB IV.pdf
Restricted to Registered users only

Download (778kB)
[thumbnail of DENILLA ESTIKA BAB V.pdf] Text
DENILLA ESTIKA BAB V.pdf
Restricted to Registered users only

Download (510kB)
[thumbnail of DENILLA ESTIKA DAFTRA PUSTAKA.pdf]
Preview
Text
DENILLA ESTIKA DAFTRA PUSTAKA.pdf

Download (514kB) | Preview
[thumbnail of DENILLA ESTIKA LAMPIRAN.pdf] Text
DENILLA ESTIKA LAMPIRAN.pdf
Restricted to Registered users only

Download (1MB)

Abstract

Lifestyle of the day lately often cause many diseases such as hypertension.
One of the drugs used to treat hypertension was metoprolol. In long-term used,
metoprolol need monitored to detect early symptoms of side effects. There was
validation metoprolol of analysis in human urine by thin layer chromatography
(TLC) – Densitometry method. The method that used in this research was in vitro.
The stationary phase was silica gel 60 F254 while the mobile phase was consist of
chloroform: methanol: ammonia (40: 60: 0,2) v / v. Detection was done with
wavelenght 282 nm. Validation parameters include of Limit of Detection (LOD)
value was 4,473 μg while Limit of Quantification (LOQ) value was 14,90 μg,
linearity was indicated by r = 0,9904. Precision was showed with Relative
Standart Deviation (RSD) value of 4.07%. The result showed that value of
recovery was 102.73%. The result showed that thin layer chromatography-
Densitometry method could be used for the analysis of metoprolol in human urine
in vitro.

Dosen Pembimbing: unspecified | unspecified
Item Type: Thesis (Bachelor)
Additional Information: Pembimbing: Dr. Pri Iswati, M.Si.,Apt. dan Dr. Asmiyenti Djalil D, M.Si.
Uncontrolled Keywords: Validation analysis method, thin layer chromatography, densitometry, metoprolol, in vitro,urine
Subjects: R Medicine > RS Pharmacy and materia medica
Divisions: Fakultas Farmasi > Farmasi S1
Depositing User: Dan Kh
Date Deposited: 19 Sep 2017 02:03
Last Modified: 08 Jul 2024 01:20
URI: http://repository.ump.ac.id/id/eprint/4221

Actions (login required)

View Item View Item