IMPLEMENTASI INTERNET OF THINGS UNTUK MONITORING KUALITAS AIR SECARA REALTIME PADA UTILITIES PT.KILANG PERTAMINA INTERNASIONAL CILACAP BERBASIS MIKROKONTROLER NODEMCU ESP 32

KHAERUDIN, RUDI (2021) IMPLEMENTASI INTERNET OF THINGS UNTUK MONITORING KUALITAS AIR SECARA REALTIME PADA UTILITIES PT.KILANG PERTAMINA INTERNASIONAL CILACAP BERBASIS MIKROKONTROLER NODEMCU ESP 32. S1 thesis, UNIVERSITAS MUHAMMADIYAH PURWOKERTO.

[img]
Preview
Text
Cover Rudi Khaerudin (1503030014).pdf

Download (17MB) | Preview
[img]
Preview
Text
Bab I Rudi Khaerudin (1503030014).pdf

Download (557kB) | Preview
[img]
Preview
Text
Bab II Rudi Khaerudin (1503030014).pdf

Download (1MB) | Preview
[img] Text
Bab III Rudi Khaerudin (1503030014).pdf
Restricted to Repository staff only

Download (979kB)
[img] Text
Bab IV Rudi Khaerudin (1503030014).pdf
Restricted to Repository staff only

Download (1MB)
[img] Text
Bab V Rudi Khaerudin (1503030014).pdf
Restricted to Repository staff only

Download (557kB)
[img]
Preview
Text
Dapus Rudi Khaerudin (1503030014).pdf

Download (561kB) | Preview
[img] Text
Lampiran Rudi Khaerudin (1503030014).pdf
Restricted to Repository staff only

Download (1MB)

Abstract

In the industrial sector, water needs are very important, one of which is as bait water on a steam boiler. In this sector, water has various functions including to produce steam as a turbine player in the generation of electrical energy. To maintain the performance and durability of the steam boiler and piping system, then the condition of this water must meet the requirements, if not met can cause problems such as the occurrence of crust, corrosion, and foam. Several parameters that are important to boiler feed water include pH, conductivity, hardness, silica content, and phosphate content. water in real time, then an internet of things system is made for real-time monitoring of water quality based on the NodeMcu ESP 32 microcontroller, the results of reading the data are displayed on the oled ssd 1306 0.96" screen and sent to the firebase cloud database which is integrated via the internet network then can be viewed through an android application that is accessed via a smartphone remotely. The results of the tests carried out are by comparing the results of measuring pH values, conductivity, and temperature with standardized Kurita brand laboratory measuring instruments. The highest average error percentage when measuring the conductivity/TDS of softener water is 25.04%

Item Type: Thesis (S1)
Uncontrolled Keywords: Internet of things, NodeMcu ESP 32, Cloud firebase, water quality