Al Ihsan, Wahyudi (2020) PENURUNAN KADAR AMONIA PADA LIMBAH CAIR OUTLET CLEAN WATER IPAL PT PERTAMINA RU IV CILACAP DENGAN METODE KOAGULASI MENGGUNAKAN KAPORIT. S1 thesis, UNIVERSITAS MUHAMMADIYAH PURWOKERTO.

[thumbnail of Cover WAHYUDI AL IHSAN_1503020007.pdf]
Preview
Text
Cover WAHYUDI AL IHSAN_1503020007.pdf

Download (1MB) | Preview
[thumbnail of Bab I WAHYUDI AL IHSAN_1503020007-2.pdf]
Preview
Text
Bab I WAHYUDI AL IHSAN_1503020007-2.pdf

Download (990kB) | Preview
[thumbnail of Bab II WAHYUDI AL IHSAN.pdf]
Preview
Text
Bab II WAHYUDI AL IHSAN.pdf

Download (8MB) | Preview
[thumbnail of Bab III WAHYUDI AL IHSAN-2.pdf] Text
Bab III WAHYUDI AL IHSAN-2.pdf
Restricted to Registered users only

Download (1MB)
[thumbnail of Bab IV WAHYUDI AL IHSAN-3.pdf] Text
Bab IV WAHYUDI AL IHSAN-3.pdf
Restricted to Registered users only

Download (1MB)
[thumbnail of Bab V WAHYUDI AL IHSAN-4.pdf] Text
Bab V WAHYUDI AL IHSAN-4.pdf
Restricted to Registered users only

Download (420kB)
[thumbnail of Daftar Pustaka  WAHYUDI AL IHSAN-5.pdf]
Preview
Text
Daftar Pustaka WAHYUDI AL IHSAN-5.pdf

Download (544kB) | Preview
[thumbnail of Lampiran WAHYUDI AL IHSAN-6.pdf] Text
Lampiran WAHYUDI AL IHSAN-6.pdf
Restricted to Registered users only

Download (6MB)

Abstract

The Processing of crude oil in the oil refinery industry is in dire need of water which is a raw material the processing process. WWTP liquid waste is waste that originates from treatment at the Wastewater Treatment Plant which contains certain characteristics. IPAL PT Pertamina RU IV Cilacap is part of the wastewater treatment unit that produces liquid waste whose parameters are still not in accordance with the quality standards of wastewater. This will have an impact on the environment if it is discharged directly without maximum processing. In this research, the process of liquid water treatment of WWTP Outlets was conducted using a coagulation method using chlorine which aims to reduce the ammonia parameters to comply with the quality standards according to LH PERMEN No.19 of 2010. The study was conducted in two experiments. The first study looked for the most influential variables of dosage, pH and stirring speed. The second study looked for optimal conditions of the required factors. The initial sample conditions before processing were pH 7.5, and ammonia 97.10 mg / L. The first study with namely dosage and stirring speed. pH became a fixed variable then dosage and stirring speed were changed in the second study. Optimal results from the five dose variations (2000, 4000, 6000, 8000, and 10000 mg / L) and stirring speed (150, 175, 200, 225, and 250 rpm) in the ammonia analysis were 1.07 mg / L Based on the results of the analysis of the ammonia parameters, it has fulfilled the quality requirements of wastewater.

Dosen Pembimbing: Damajanti, Neni | nidn0609027001
Item Type: Thesis (S1)
Uncontrolled Keywords: Outlet Clean Water, WWTP, Ammonia, Coagulation, Chlorine.
Subjects: T Technology > TP Chemical technology
Divisions: Fakultas Tekniik Dan Sains > Teknik Kimia S1
Depositing User: Agus Imam
Date Deposited: 08 Sep 2022 07:39
Last Modified: 21 May 2024 06:35
URI: http://repository.ump.ac.id/id/eprint/14029