ANALISIS PERKUATAN TOWER SITE GREENFIELD JENIS SELF SUPPORT TOWER (SST)

SANTOSA, IRWAN DWI (2014) ANALISIS PERKUATAN TOWER SITE GREENFIELD JENIS SELF SUPPORT TOWER (SST). Bachelor thesis, UNIVERSITAS MUHAMMADIYAH PURWOKERTO.

[img]
Preview
Text
IRWAN DWI SANTOSA COVER.pdf

Download (598kB) | Preview
[img]
Preview
Text
IRWAN DWI SANTOSA BAB I.pdf

Download (524kB) | Preview
[img]
Preview
Text
IRWAN DWI SANTOSA BAB II.pdf

Download (559kB) | Preview
[img] Text
IRWAN DWI SANTOSA BAB III.pdf
Restricted to Repository staff only

Download (527kB)
[img] Text
IRWAN DWI SANTOSA BAB IV.pdf
Restricted to Repository staff only

Download (547kB)
[img] Text
IRWAN DWI SANTOSA BAB V.pdf
Restricted to Repository staff only

Download (511kB)
[img]
Preview
Text
IRWAN DWI SANTOSA DAFTAR PUSTAKA.pdf

Download (511kB) | Preview
[img] Text
IRWAN DWI SANTOSA LAMPIRAN.pdf
Restricted to Repository staff only

Download (9MB)

Abstract

Growth of telecommunications world of vital importance for corporate world circle. Effect of growth of telecommunications world of a lot of we meet many telecommunication towers, because telecommunication tower is one of especial media in the world of communications without cable. local government has issued new regulations on the planning and implementation of BTS towers in the town. The new regulation contains the shared use of the tower which requires the cooperation of multiple vendors to use a single phone tower. (02/PER/M.KOMINFO/3/2008). Planning tower, load which having an effect on dominantly is wind load. Wind burden reckoned by based on regulation Telecommunications Industry Association and Electronic Industries Alliance (TIA/EIA) Standard Structural Standards For Steel Antenna Tower and Supporting Structures (TIA / EIA-222-f) analysis Tower conducted by MS TOWER V6 software. Intention of this writing to look for the alternative of strength tower can arrest detain the burden addition. This strength use the existing tower with the height 43 metre, with the antenna burden of early 2 unit of microwave antenna and 6 unit of sector antenna. From result analyse strongly is addition redundant at height 7.5 metre and 12.5 metre, So that capacities tower become 4 unit of microwave antenna and 12 unit of sector antenna. Twist = 0.0014 < 0.5, sway = 0.1920 < 0.5, displacement = 0.0800 < 0.2150, stress ratio = 0.988 < 1.000.

Item Type: Thesis (Bachelor)
Additional Information: Pembimbing: Amris Azizi, ST, M.Si dan Sulfah Anjarwati, ST, MT
Uncontrolled Keywords: strengthening, existing tower, wind load
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Divisions: Fakultas Teknik > Teknik Sipil
Depositing User: Danarto Kh
Date Deposited: 16 Oct 2017 05:29
Last Modified: 16 Oct 2017 05:29
URI: http://repository.ump.ac.id/id/eprint/4727